This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
|
handover:rd2001 [2020/01/15 22:46] Pradyumna Kiran Kummamuru |
handover:rd2001 [2020/01/16 18:24] (current) Pradyumna Kiran Kummamuru |
||
|---|---|---|---|
| Line 12: | Line 12: | ||
| * Power failure at MtP. Dish came back on source at 2217UT. | * Power failure at MtP. Dish came back on source at 2217UT. | ||
| * 70K stage temperature values shoot up from time to time. Display/sensor issue? | * 70K stage temperature values shoot up from time to time. Display/sensor issue? | ||
| - | * Power failure at around 2230UT. Restarted system at 2243UT. | + | * Power failure at around 2230UT. Restarted system at 2243UT. Scans 015-2229 and 015-2242 affected. |
| + | * 2250UT - Wind stowed is what the live page indicated. Back on at 2259UT. Scan 015-2250 missed. | ||
| + | * 0733UT mk5cn: time-out, connection closed occasionally happened after a few "recording stopped". Recording started normally for the subsequent scans. | ||
| + | * 1606UT - looks like it fails to connect to mk5, auto correlation plot shows correct timestamp but scan number "-alpha-", warning "mk5cn: error opening, mark 5 probably not running, see above for error" without error. disk_pos doesn't update. One of the Mk5hb light flickered, ip switching mk5hb made one of the light on module flickers. (Lim) | ||
| + | * Problem not solved till the end of schedule. Scans very likely affected. (Lim) | ||