User Tools

Site Tools


operations:handover

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Handover notes

Please use this page to write up any notes on anything that needs to be passed on to the next observer or should go into the end of experiment message.

Notes should be placed below the horizontal line as a new blog entry.

Continuing problems should be copied to the Current Issues page.

**Template for Handover notes:**

Be sure to add any specific notes about the experiment if required, for example “Special back end configuration for x reason”. Put as much detail as you can - the more the better.

It is ESSENTIAL to put your name after EVERY entry. Copy and paste the template into the new handover notes

====== Experiment Name ======

**Hobart 12m**

Disk VSN: abc-123 | Data volume at beginning: 2.34 GB

   * 1300UT a comment from me (user)

**Katherine 12m**

Disk VSN: | Data volume at beginning:  GB

   * 

**Yarragadee 12m**

Disk VSN: | Data volume at beginning:  GB

   * 1300UT Experiment started okay (JMc).

Format for entering a comment It is important to stick to this formula - there is a good reason we need this information, so please include it!

Time stamp in UT * Comment * (Your Name)

For Example:

20:00UT: Wind stows, Missed scans 012-3456 to 012-3457 (Jim)

20:50UT: Mark5 lost connection, had to restart Mark5 and reconfigure DBBC, called Jamie on call to fix, missed scans 012-3456 to 012-4567 (Jim)

Again - as much detail as you can. It is important to remember that these notes will be sent to the correlator, so please make sure they make sense to others.


R4914

Yarragadee 12m

Disk VSN: USN-0192/2000 | Data volume at beginning: 0.224 GB

  • connection to Yg maser down (Patrick)
  • 18:30UT - Experiment started OK (Patrick)
2019/10/01 17:08 · Tiege McCarthy · 0 Comments
R1914

Yarragadee 12m

Disk VSN: HOB+0025/6000 | Data volume at beginning: 0.321 GB

DBBC software needed a couple of restarts due to the well known TPI overflow issue when doing a pointing check.

  • 17:00UT - Experiment started OK (Tiege)
  • 13:20UT - Network connection between ops8 and pcfsyg down. Can't connect to yg-via-internode. Monitoring, in case it comes back up. (Patrick)
  • 14:20UT - Network restored. Contacted Yg and checked everything was operational on their end. Asked them to reboot/power cycle router, but they weren't sure which one (neither was I). Just about to call on-call person, then it came back up. (Patrick)
2019/09/30 15:01 · Tiege McCarthy · 0 Comments
R4913

Yarragadee 12m

Disk VSN: MED-0026/2000 | Data volume at beginning: 0.385 GB

DBBC software needed a couple of restarts due to the well known TPI overflow issue when doing a pointing check.

  • 18:30UT - Experiment started OK (Tiege)
2019/09/26 18:39 · Tiege McCarthy · 0 Comments
RD1910

Hobart 26m

Disk VSN: HOB+0057 | Data volume at beginning: 657 GB

  • 18:00UT - Experiment started OK (Jay)
  • 04:50UT - Wrong receiver on axis. Schedule halted to correct this. (JMc)
  • 04:59UT - Good data after this time. 4.8 GHz receiver went on axis ~01:20 (JMc)
2019/09/25 17:42 · Tiege McCarthy · 0 Comments
T2134

Hobart 26m

Disk VSN: HOB+0057 | Data volume at beginning: 0.112 GB

  • 17:30UT - Experiment started OK (Prad)
  • 1942UT -Mark 5B not synced. Scan 267-1942a may have been affected (Prad).
  • Something with the wx command. Keep getting 'Problem connecting to metserver socket' and 'illegal error class code' (Prad).
  • 01:54 UT halted schedule for Agilent service/test missed scan 268-0154a onward (warren)
  • 03:21 UT resumed schedule (w)
  • 06:45 UT data 45 GB short due to halt (w)
  • 07:41 UT Hobart Tsys are all over/underflowing (Patrick)

Yarragadee 12m Disk VSN: USN-0095 | Data volume at beginning: 1315.606 GB

  • 17:30UT - Experiment started OK (Prad).
2019/09/24 17:34 · Tiege McCarthy · 0 Comments
R1913

Yarragadee 12m

Disk VSN: USN-0095 | Data volume at beginning: 12 GB

  • Note: Record using jive5ab, please do not start DIMnino during next experiment setups or it will crash the mk5. If need to use dimino, go to pcfsyg and ctrl+c on the upper right terminal and run pkill jive5ab before starting it.
  • TPI overflow problem again on pointing check. Restarted dbbc software a few times, dbbc=pps_sync sent a few times, didn't work.
  • 1700UT Experiment started okay (Lim).
  • 1700UT error m5 -900 not whilst recording and error m5 -906 mark5 return code 6: inconsistent or conflicting request seems to happen on every scan.
  • The above error is due to mk5=bank_set? being called during midob. Commented out mk5=bank_set? in midob and moved it to preob. Temporary fix documented here (Lucas)
2019/09/23 07:30 · Tiege McCarthy
/home/www/auscope/opswiki/data/pages/operations/handover.txt · Last modified: 2018/10/29 16:27 by Jesse Swan