User Tools

Site Tools


operations:handover

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Handover notes

Please use this page to write up any notes on anything that needs to be passed on to the next observer or should go into the end of experiment message.

Notes should be placed below the horizontal line as a new blog entry.

Continuing problems should be copied to the Current Issues page.

**Template for Handover notes:**

Be sure to add any specific notes about the experiment if required, for example “Special back end configuration for x reason”. Put as much detail as you can - the more the better.

It is ESSENTIAL to put your name after EVERY entry. Copy and paste the template into the new handover notes

====== Experiment Name ======

**Hobart 12m**

Disk VSN: abc-123 | Data volume at beginning: 2.34 GB

   * 1300UT a comment from me (user)

**Katherine 12m**

Disk VSN: | Data volume at beginning:  GB

   * 

**Yarragadee 12m**

Disk VSN: | Data volume at beginning:  GB

   * 1300UT Experiment started okay (JMc).

Format for entering a comment It is important to stick to this formula - there is a good reason we need this information, so please include it!

Time stamp in UT * Comment * (Your Name)

For Example:

20:00UT: Wind stows, Missed scans 012-3456 to 012-3457 (Jim)

20:50UT: Mark5 lost connection, had to restart Mark5 and reconfigure DBBC, called Jamie on call to fix, missed scans 012-3456 to 012-4567 (Jim)

Again - as much detail as you can. It is important to remember that these notes will be sent to the correlator, so please make sure they make sense to others.


CRD103

Hobart 26m

Disk VSN: HOB+1003 | Data volume at beginning: 0.0 GB

  • 1730UT Experiment started okay (Lim)
  • 1941UT Autocorrelation did not look gook, reprogrammed DBBC and Sync fmset after scan 176-1936, missed scans: 176-1943 and 176-1951. (Lim)
  • 2140UT formatter-gps time was constantly drifting since last dbbc reconfiguration. drifted to ~0.9us, Solved by Rebooting mk5 and dbbc. Missed scans: 176-2136, 176-2143, 176-2149(Lim)
  • 0422-0511 - Sync Error and associated 1 second offset. No obvious cause. DBBC power cycled and reconfigured. (JMc)

Katherine 12m

Disk VSN: HOB+0133 | Data volume at beginning: 0.0 GB

  • 1730UT Experiment started okay (Lim)

Yarragadee 12m

Disk VSN: HOB+1008 | Data volume at beginning: 0.0 GB

  • 1730UT Experiment started okay (Lim).
2019/06/25 17:46 · Earl Lester
R1900

Katherine 12m

Disk VSN: HOB+0059 | Data volume at beginning: 0.384 GB

  • 1700UT - Experiment started okay (Patrick)

Yarragadee 12m

Disk VSN: HAY-0144 | Data volume at beginning: 0.385 GB

  • 1630UT - TPI Overflow error after attempting to run fivept. Fixed by restarting DBBC software (Patrick)
  • 1700UT - Experiment started okay (Patrick)
  • 2346 - Schedule halted, antenna stowed for brief on-site maintenance. (JMc)
  • 2356 - Schedule resumed, telescope onsource again (JMc)
  • No useful data 2346-2356 (JMc)
2019/06/24 06:36 · Patrick Yates · 0 Comments
R4899

Katherine 12m

Disk VSN:IPA-0018/2000 | Data volume at beginning: 0.192 GB

  • 1830UT - Experiment started OK. (Tiege)

Yarragadee 12m

Disk VSN: CURT-001/2400 | Data volume at beginning: 0.641 GB

  • 1815UT - Getting the following error “ probably no such disk” when running checkmk5 on the new disk. Data seems to be recording onto the disk fine, and checkmk5 still completes, with autocorrs looking good. Wiki says it is safe to ignore. (Tiege)
  • 1830UT - Experiment started OK. (Tiege)
2019/06/20 18:25 · Earl Lester · 0 Comments
aua053

Hobart 26m

Disk VSN: GSFC+012/8000 | Data volume at beginning: 0.641 GB

  • 1800UT S/X reciever 70K stage is still warm (~100K). Can't cool any further. Vacuum and cryogenics pressures are both optimal. (Patrick)
  • 1800UT Experiment started OK (Patrick).
  • 2200UT Large disk offset noted, however Jamie mentioned that disk usage summaries for this experiment are probably incorrect (Patrick)

Katherine 12m

Disk VSN:HOB+0126/32000 | Data volume at beginning: 6964.341 GB

  • 1800UT Experiment started OK. (Patrick)
  • 2200UT Large disk offset noted, see above for Hobart (Patrick)
  • Late to source sometimes (see WARNING: ONSOURCE status is SLEWING! errors) (Patrick)

Yarragadee 12m

Disk VSN: HOB+0103/16000 | Data volume at beginning: 0.641 GB

  • 1800UT Experiment started okay. (Patrick)
  • 2200UT Large disk offset noted, see above for Hobart (Patrick)
  • Late to source sometimes (see WARNING: ONSOURCE status is SLEWING! errors) (Patrick)
2019/06/19 17:26 · Earl Lester · 0 Comments
aov036

Hobart 26m

Disk VSN: MAT+0004/8000 | Data volume at beginning: 0 GB

  • 1730UT Experiment started OK (Katie).
  • After first scan received error “previous source not reached before new source commanded..etc”. But did not happen again. (Katie)
  • 00:00 UT 70 K receiver stage at 100 K, will not cool further. supply pressure and vacuum pressure optimal (warren)

Katherine 12m

Disk VSN:HOB+0126/32000 | Data volume at beginning: 0 GB

  • 1730UT Experiment started OK. (Katie)
  • While setting up eRemote lost connection but opening it and closing it a couple of times fixed it.(Katie)

Yarragadee 12m

Disk VSN: HOB+0041/6000 | Data volume at beginning: 0 GB

  • 1730UT Experiment started okay. (Katie)
  • 1728UT Ran out of space on module during final scan, 170-1716 (Patrick)
2019/06/18 22:15 · Earl Lester · 0 Comments
R1899

Katherine 12m

Disk VSN: HAY-0030/2000 | Data volume at beginning: 0.00 GB

  • 17:00 UT Experiment started okay (Lucas).
  • 04:00 UT vsn not set on module, vsn set (Warren)

Yarragadee 12m

Disk VSN: SHAO-023/2000 | Data volume at beginning: 0.00 GB

  • 17:00 UT Experiment started okay (Lucas).
  • 22:00 UT VNC to maser not working; call Yg control room to get them to look at maser computer screen (Warren)
2019/06/17 17:09 · Earl Lester · 1 Comment