User Tools

Site Tools


blog:mark5_upgrade_for_cont14

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
blog:mark5_upgrade_for_cont14 [2014/03/19 00:42]
Jamie McCallum
blog:mark5_upgrade_for_cont14 [2014/03/20 05:31] (current)
Jim Lovell
Line 2: Line 2:
  
 The firmware/​software upgrade to the Mark5A and Mark5B+ units has been carried out for mkv, mk5hb and mk5yg. The new version seems to have some compatibility issues with previously recorded modules - DirList gives all scan pointers as zero. For this reason, mk5streamhb has not been upgraded, in order to be able to easily read pre-March 19 modules (AUST19,​AUST20,​ohig)?​ The new version of fuseMk5 can work with the new UserDir size but has not been tested. ​ The firmware/​software upgrade to the Mark5A and Mark5B+ units has been carried out for mkv, mk5hb and mk5yg. The new version seems to have some compatibility issues with previously recorded modules - DirList gives all scan pointers as zero. For this reason, mk5streamhb has not been upgraded, in order to be able to easily read pre-March 19 modules (AUST19,​AUST20,​ohig)?​ The new version of fuseMk5 can work with the new UserDir size but has not been tested. ​
 +
 +Info for observers: ​
 +The upgrade changes the maximum number of scans that can be recorded onto a module from 2^10 to 2^16. Not everywhere has completed this though, so to maintain backwards compatibility you need to issue this command from the FS before starting a recording on an empty module
 +
 +mk5=protect=off\\
 +mk5=reset=erase:​s
 +
 +This sets the scan list back to the short format with 2^10 scans maximum. This is necessary for all modules for the next few months, and critical for those sent off to Washington.
 +
 +Also, can you include this message in the start/stop messages:
 +
 +"The mark5B+ was upgraded 19/3/14 and is using mark5 v3.0.1 software, Amazon v16.37 firmware, and FPGAConfigVersion 1.08."
 +
  
 {{tag>}} {{tag>}}
/home/www/auscope/opswiki/data/attic/blog/mark5_upgrade_for_cont14.1395189771.txt.gz · Last modified: 2014/03/19 00:42 by Jamie McCallum