User Tools

Site Tools


handover:aua039

This wiki is not maintained! Do not use this when setting up AuScope experiments!

AUA039

Hobart 26 m

  1. Problem with hydraulic part, out of the experiment
  2. 06:00 UT Back on with the experiment. Everything seems to be fine. (Katie)

Katherine 12m

Disk VSN: HOB+0121/32000 | Data volume at beginning: 9598.437 GB

  1. 18:00:00 Experiment started OK (mas).
  2. 18:08:44 Constantly received warning#waiting at limit (scan no00003), warning:error an -103 pointing computer tracking errors are too large, warning: error qo -301 warning onsource status is slewing, and alarm: error, f1 previous source in this schedule not reached before new source was commanded at 18:13:18 UT(mas)
  3. 18:41:22, 18:47:14 & 19:01:19 WARNING: error 5t -301 don't change mode while recording, use disk_record=off first or (dangerous) use disk_record_ok as the sixth parameter
  4. 18:41:24 & 18:47:16, 19:01:21 WARNING: error an -103 pointing computer tracking errors are too large
  5. 18:41:24, 18:47:16 & 19:01:21 WARNING: error qo -301 warning: onsource status is slewing
  6. 19:37:52 Constantly received warning#waiting at limit (scan no19-no 22), called Jamie and halt the schedule (19:45:42.7 UT). Schedule resume at scan no 23 (19:49:09 UT)
  1. 23:51:51 Constantly received warning#waiting at limit (scan no0065), warning:error an -103 pointing computer tracking errors are too large, warning: error qo -301 warning onsource status is slewing, and alarm: error, f1 previous source in this schedule not reached before new source was commanded at 23:54:34 UT(Simin)
  2. 23:58:38 Constantly received warning#waiting at limit (scan no0065), warning:error an -103 pointing computer tracking errors are too large, warning: error qo -301 warning onsource status is slewing, and alarm: error, f1 previous source in this schedule not reached before new source was commanded at 23:58:48 UT(Simin)
  3. 01:14:57 Constantly received warning#waiting at limit (scan no0076), warning:error an -103 pointing computer tracking errors are too large, warning: error qo -301 warning onsource status is slewing, and alarm: error, f1 previous source in this schedule not reached before new source was commanded at 01:17:34 UT(Simin)
  4. 01:22:09 Constantly received warning#waiting at limit (scan no0079), warning:error an -103 pointing computer tracking errors are too large, warning: error qo -301 warning onsource status is slewing, and alarm: error, f1 previous source in this schedule not reached before new source was commanded at 01:24:08 UT(Simin)
  5. Almost every 10 scans the same errors and warnings as above have occurred.
  1. 09:46 UT System monitor warning: No Monica data available: pcfsyg.mon.pcfsyg.wth.temperature (Katie)
  2. 10:35 UT Same errors occur every 10 or so scans. Jamie has said problem is with the schedule file. (Katie)

Yarragadee 12m

Disk VSN: HOB+0118/32000 | Data volume at beginning: 3.718 GB

  1. 18:00:00 Experiment started OK (mas).
  2. 18:08:34 Constantly received warning#waiting at limit (scan no00003), warning:error an -103 pointing computer tracking errors are too large, warning: error qo -301 warning onsource status is slewing, and alarm: error, f1 previous source in this schedule not reached before new source was commanded at 18:13:14 UT(mas)
  3. 18:47:14 WARNING: error 5t -301 don't change mode while recording, use disk_record=off first or (dangerous) use disk_record_ok as the sixth parameter
  4. 18:47:17 WARNING: error an -103 pointing computer tracking errors are too large
  5. 18:47:17 WARNING: error qo -301 warning: onsource status is slewing!
  6. 19:37:52 Constantly received warning#waiting at limit (scan no19-no 22), called Jamie and halt the schedule (19:45:42.7 UT). Schedule resume at scan no 23 (19:49:09 UT)
  7. 23:51:41 Constantly received warning#waiting at limit (scan no0065), warning:error an -103 pointing computer tracking errors are too large, warning: error qo -301 warning onsource status is slewing, and alarm: error, f1 previous source in this schedule not reached before new source was commanded at 23:54:34 UT(Simin)
  8. 01:14:45 Constantly received warning#waiting at limit (scan no0076), warning:error an -103 pointing computer tracking errors are too large, warning: error qo -301 warning onsource status is slewing, and alarm: error, f1 previous source in this schedule not reached before new source was commanded at 01:17:34 UT(Simin)
  9. 01:17:43 Constantly received warning#waiting at limit (scan no0079), warning:error an -103 pointing computer tracking errors are too large, warning: error qo -301 warning onsource status is slewing, and alarm: error, f1 previous source in this schedule not reached before new source was commanded at 01:24:08 UT(Simin)
  10. Almost every 10 scans the same errors and warnings as above have occurred.
  1. 09:46 UT System monitor warning: No Monica data available: pcfsyg.mon.pcfsyg.wth.humidity (Katie)
  2. 10:35 UT Same errors occur every 10 or so scans. Jamie has said problem is with the schedule file. (Katie)
/home/www/auscope/opswiki/data/pages/handover/aua039.txt · Last modified: 2018/03/08 10:41 by Jesse Swan