  • 07:00 UT - First scan missed due to messing around with mark 5. Numerous hard and soft reboots done to get it to behave. Literally had a fit for no reason. (Ellen)
  • 03:55 UT - Alarm: Delay through DBBC has changes. Delaylive window shows a rapid change. DDBC was reset (Lucia).

Hobart 26m (Ho)

  • 07:00 UT - Experiment started ok. (Ellen)
  • 08:53 UT - Alarm reporting “previous source in this schedule not reached before new source was commanded” after stopping recording for scan 336-0853. Slewing during scan. No alarms following this. (Ellen)
  • 10:24 UT - Another alarm for slewing during scan 336-1023. (Ellen)
  • 11:21 UT - Slewing during scan 336-1120. (Ellen)
  • 23:50 UT - schedule halted for maintenance. Brett needed to cool the multifeed. I think the recorded kept running thorugh the schedule halt. now 302 GB too much. Adjusted disk offset in Log monitor accordingly. Scans lost 23:27-23:51. (Lucia)
  • 01:13 UT - Wind stow. Lost scans: 337-0058 through 337-0114 inclusive. (Lucia)
  • 01:30 UT - wind stow. Ongoing, schedule halted at 02:03 UT, resumed at 02:42 UT. Lost scans: 337-0131 through 337-0249. First good scan 337-0251. (Lucia)
  • 04:30 UT - schedule halted for antenna maintenance (Brett). Lost scans: 337-0416 through 337-0433 (Lucia)