Hobart 12m:

Disk VSN: HOB+0118

Data volume at beginning: 24161.032 GB

  • 07:00 UT during setup, both pcfshb and mk5hb hung up when rebooting, though Jamie was able to fix both onsite. (NH)
  • 17:00 UT Experiment otherwise seems to have started Okay. (NH)
  • 17:30 UT Tsys values are all ?????? or in the thousands. (NH)
  • 19:15 UT Getting quite a few of “ERROR s1 -104 ifpcn: time-out, connection closed”, consequently each scan was starting late and missing data. Restarting Rxmon did not fix the problem. (NH)
  • 22:30 UT Jamie fixed the ifpcn errors by fixing up monica. First full scan is 117-2239.
  • 23:00 UT data recording is now 50 GB behind. (Lucia)
  • 23:45 UT Generator state in the System monitor was 'in auto off', but orange. Called Warren at Mt Pleasant, the generator is ok. Restarting the System monitor fixed it. (Lucia)
  • 04:09 UT got a couple of ACU-Computer time errors. All good again after a few minutes (Lucia)