Katherine 12m:

Disk VSN: HOB+0105

Data volume at beginning: 10141 gb

  • 15:52 UT Suddenly had many instances of the following error “WARNING: error st -27 computer acu time difference exceeded 0.25 seconds, see value above.”. It eventually stopped, all seems okay. Wiki says this error arises when etransfers are going on, can be safely ignored. (Arwin)
  • 17:00 UT Experiment started OK (Arwin)
  • Setup code was “setup8f” not “setupsx” (Arwin)
  • Temp sensor on system monitor not working (Arwin)

Yarragadee 12m:

Disk VSN: HOB+0102

Data volume at beginning: 10141 gb

  • 17:00 UT Experiment started OK (Arwin)
  • 17:05 UT Mark5 lost connection and fmset would not display anything. Halted the schedule. Tried restarting the fs and Dimino but to no avail. Jamie rebooted mark5 and Dimino and made sure ntpq -nq servers were sensible. Fmset came back at this point. Restarted the schedule. Scans missed 179-1705 - 179-1829. (Arwin)
  • 18:32 UT started recording again. (Arwin)
  • Humidity showing up as zero despite some light rain in the area, sensor not working? (Arwin)