This wiki is not maintained! Do not use this when setting up AuScope experiments!
This is an old revision of the document!
R1757
Hobart 12m
Data Recorded to MED-0038, disk_pos 0 GBs
17:00 UT - Experiment started OK. (Tiege)
Katherine
Data Recorded to USN-0069, disk_pos 0 GBs
17:00 UT - Experiment started OK (Tiege)
~17:30 UT - Noticed that I was consistently getting the warning “WARNING: error sc -13 setcl: formatter to fs time difference 0.5 seconds or greater”. Tried fixing this in all the ways listed on the wiki. mk5=dot? returned large numbers for the last value. Monitoring fmset, the times seemed to be synced when data was not being recorded, however, when recording started mk5 became heavily out of sync. After trying multiple times to fmset, and to restart dimino on mk5ke, I attempted to power cycle the mk5ke using the ip switch. Unfortunately after the power cycle, I have been unable to ssh into mk5ke. As a work-around (hopefully), I have switched over to mk5-2ke for this experiment by terminating the fs, editing
Yarragadee
Data Recorded to USN-0020, disk_pos 52.1 GBs
17:00 UT - Experiment started OK (Tiege)
You could leave a comment if you were logged in.