DBBC Power Measurement

New Zealand DBBC 09/06/2011

Testing of DBBC power measurement device reveals that it has a logarithmic output response!!

Update:13/6/2011: Logarithmic response verified, 37 mV/dB according to data sheet hmc610lp4-datasheet.pdf

Presumably the DC output from this chip is sampled by an ADC. Would not think it likely that this (ADC) has significantly non linear behaviour. Conclude that the numbers provided by DBBC are proportional to power in dB

See attached spreadsheet and notes below:

linearity-test-jun-2011.xls

We have used this to modify antcn in the Field System so that the DBBC can be used to provide power measurements for “fivept”, “onoff” and “acquire”. We have thus used for pointing which can be used by the Field System pointing model.

I'll attach the FS s/w for this in due course.