Katherine has completed r1606

The log from experiment r1606 has been copied to ivsopar.obspm.fr:/pub/ivsincoming/ Formatter (H-maser) leads GPS by 9.5929 microsec at 2013.281.16:59:32.03

Additional experiment notes: Recorded 1749.48 GB to module NRCAN-05 using the Mark5B+ recorder. The Module is being sent to BONN using eTransfer.

Known problems: at 08:13 UT e-remote started disconnecting and reconnecting repeatedly. at 13:17 the error “Computer ACU time difference exceeded 0.25 seconds” appeared repeatedly for a couple of mins but the times all match and the delay was small enough

Missed Scans: no

Observers: Dave, Imogen, Ellen

Regards, Ellen