This shows you the differences between two versions of the page.
Both sides previous revision Previous revision | |||
operations:agenda2017_08_31 [2017/08/31 02:48] Patrick Yates |
operations:agenda2017_08_31 [2017/08/31 03:09] (current) Patrick Yates |
||
---|---|---|---|
Line 3: | Line 3: | ||
Chair: Patrick | Chair: Patrick | ||
- | Present: | + | Present: Bryn, Ross, Jonny, Tiege |
- | Apologies: Lucas, Jesse, Liz, Mas | + | Apologies: Lucas, Jesse, Liz, Mas, Arwin |
- | Absent: | + | Absent: Jamie, Lucia, Warren, Ellen |
General Issues: | General Issues: | ||
Line 18: | Line 18: | ||
* R1806 - Error in way autocorrelation script was being called caused mk5 errors. | * R1806 - Error in way autocorrelation script was being called caused mk5 errors. | ||
* Ho | * Ho | ||
- | * AUA025 - DBBC issues at beginning of experiment. Post-preob check displayed many errors. | + | * AUA025 - DBBC issues at beginning of experiment. |
- | * RD1708 - Needed to restart field system. Procedure file was wrong. | + | * To record just on Hb mk5, terminate both Ho and Hb fs then run Jamie's script. |
- | * RD1708 - Module ran out of space | + | * Post-preob check displayed many errors. |
+ | * RD1708 - Needed to restart field system. Had to run field system on ops8. Procedure file was wrong - not our fault. Using an older one always seems to work. | ||
+ | * RD1708 - Module ran out of space - person on day shift checks modules are ready for following day. mk(4/v?) rack sometimes fails if 2 modules are in. Day shift should check disk space. | ||
+ | * 20K consistently reports high temperatures. 70K occasionally reports one high measurement. | ||
* Yg | * Yg | ||
* Humidity sensor still needs replacing | * Humidity sensor still needs replacing | ||
- | * AUA025 - Proc file not on machine | + | * AUA025 - Proc file not on machine. Exp not on IVS so drudged manually, Jamie forgot to transfer final prc file. |
- | + | ||
- | * Ke | + |