This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
operations:agenda2019_01_25 [2018/01/25 01:41] Arwin Kahlon |
operations:agenda2019_01_25 [2018/01/25 02:17] (current) Jesse Swan |
||
---|---|---|---|
Line 1: | Line 1: | ||
**Chair:** | **Chair:** | ||
- | **Attended:** | + | **Attended:** Everybody <3 |
**Apologies:** | **Apologies:** | ||
Line 12: | Line 12: | ||
* Hobart 26m receiver temperature issues during aov019. | * Hobart 26m receiver temperature issues during aov019. | ||
+ | * Cryo fix has been implemented (temporarily), this appeards to be redular issues with day-time temperature flucuations. Brett did some pumping to sort this out, monitor temps as required during shifts. | ||
* IF settings different for ho 26m with the mk5 backend. Check iread to see if power levels are attained | * IF settings different for ho 26m with the mk5 backend. Check iread to see if power levels are attained | ||
+ | * AOV018 AOV019: add documentation for nominal IF values, check power levels (''iread'' as required during setup and observations) | ||
* No end of experiment checklist popped for r1826 ke and yg | * No end of experiment checklist popped for r1826 ke and yg | ||
+ | * just an omission from an edited schedule file. (jamie to double check) | ||
* ''ERROR sc -13 setcl formatter to FS time difference 0.5 seconds or greater'' appearing for ho and ke, sometimes even with fs amd mk5 times being in sync | * ''ERROR sc -13 setcl formatter to FS time difference 0.5 seconds or greater'' appearing for ho and ke, sometimes even with fs amd mk5 times being in sync | ||
+ | * FMset should fix this -- remember to only do ''fmset'' between recordings (Jamie will look into it further) | ||
+ | | ||
+ | * clkoff and maserdelay should now be working on Ho with the mk5hb backend. | ||
+ | |||
+ | * **Clean the auscope room after your night shift, this is a professional work environment. | ||
+ | ** | ||
+ | |||