User Tools

Site Tools


operations:documentation_cont14_module_swap

This wiki is not maintained! Do not use this when setting up AuScope experiments!

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
operations:documentation_cont14_module_swap [2014/05/01 04:49]
Jim Lovell
operations:documentation_cont14_module_swap [2014/11/25 03:35] (current)
Jim Lovell
Line 1: Line 1:
-====== Module Swaps in CONT14 ======+====== Module Swaps in CONT14 ​and AUST Marathon======
  
 Module swaps should be coordinated with local staff at the observatories and should //only// occur at the start of a System Check period. Remember that not all System Check periods require a module swap. Before a module is swapped, you and the local person **must** agree, on the phone, that both modules are idle. Module swaps should be coordinated with local staff at the observatories and should //only// occur at the start of a System Check period. Remember that not all System Check periods require a module swap. Before a module is swapped, you and the local person **must** agree, on the phone, that both modules are idle.
Line 9: Line 9:
   * Ask the local person to turn the key on the used module and swap it with a blank one of the correct size.   * Ask the local person to turn the key on the used module and swap it with a blank one of the correct size.
   * Wait for three green lights above the new module to indicate it is powered up and ready.   * Wait for three green lights above the new module to indicate it is powered up and ready.
-  * If this station is NOT Katherine you will want to continue with the old, partially filled module. So confirm you have the right one with a <​code>​mk5=vsn?</​code>​ and if it isn't, change to the correct one with a <​code>​mk5=bank_set=inc</​code>,​ wait about 10 sec, then do and another <​code>​mk5=vsn?</​code>​ +  * You will want to continue with the old, partially filled module, so confirm you have the right one with a <​code>​mk5=vsn?</​code>​ and if it isn't, change to the correct one with a <​code>​mk5=bank_set=inc</​code>,​ wait about 10 sec, then do and another <​code>​mk5=vsn?</​code>​ 
-  * Make a note in the log that a new module has been inserted into Bank A or B, and say which bank is currently active. Please include VSN codes in the message and in the table on the [[operations:​documentation_cont14_timetable|Observation Timetable and Modules]] page. +  * Make a note in the log that a new module has been inserted into Bank A or B, and say which bank is currently active. Please include VSN codes in the message and in the table on the [[operations:​documentation_austral15day_overview#​module_usage|Module usage page]] page. 
-  * Send an email to transfers@postoffice.maths.utas.edu.au so that we know what's happened+  * Send an email to auscope-operations@list.utas.edu.au so that we know what's happened
  
 Note that you can view the Mark5 recorder and the status of the modules remotely using the control room Pan-Tilt-Zoom (PTZ) web cameras: Note that you can view the Mark5 recorder and the status of the modules remotely using the control room Pan-Tilt-Zoom (PTZ) web cameras:
/home/www/auscope/opswiki/data/attic/operations/documentation_cont14_module_swap.1398919798.txt.gz · Last modified: 2014/05/01 04:49 by Jim Lovell