operations:ips [2012/11/28 23:57]
jayb created
operations:ips [2014/07/19 02:10]
Anita Titmarsh
Line 3: Line 3:
  
 They are: They are:
-</code>+<​code>​
 ipshb.phys.utas.edu.au ipshb.phys.utas.edu.au
 ipske.phys.utas.edu.au ipske.phys.utas.edu.au
Line 23: Line 23:
  
 In this case we are restarting plug 5. In this case we are restarting plug 5.
 +
 +(Note that scripts exist at Katherine to [[operations:​documentation:​ke_lights|control the lights and reset the webcam]]) ​
 +
 +After this you will need to restart and reconfigure the DBBC, instructions are here:
 +
 +http://​auscope.phys.utas.edu.au/​opswiki/​doku.php?​id=operations:​documentation.dbbcsetupivs_9.10.5
 +
 +In econtrol to get the DBBC talking to the mk5:
 +<​code>​
 +setupsx
 +</​code>​
 +
 +In pcfs[hb|ke|yg] sync everything:
 +<​code>​
 +fmset
 +</​code>​
 +
 +In econtrol reset the counters for clkoff and maserdelay:
 +<​code>​
 +counter
 +</​code>​
 +
 +A clkoff and maserdelay would also be wise to check the delays are OK and stable.
 +
 +
 +List of ports available for on/off/boot at Katherine:
 +<​code>​
 +Plug Name Status On - Installed 2 of power distribution units (PDU). These are like an 8 way power board that have individually switched outputs. They can be switched from a web interface at the following 2 links:
 +\\ [[http://​pdu1ke.phys.utas.edu.au/​outlet.htm|pdu1ke.phys.utas.edu.au/​outlet.htm]]
 +\\ [[http://​pdu2ke.phys.utas.edu.au/​outlet.htm|pdu2ke.phys.utas.edu.au/​outlet.htm]]
 +
 +The user is admin and the password is the same one we use for the internet power switches.
 +\\ PDU1KE so far has wifi, cduke (network maint computer) and the interior light.
 +\\ PDU2KE so far has mk5-2ke and the GPIB controller.
 +Off Boot Default
 +1 pcfske ON ON
 +2 mk5ke ON ON
 +3 timeke ON ON
 +4 windke ON ON
 +5 DBBC ON ON
 +6 Camera ON ON
 +7 ExteriorLight OFF OFF
 +8 AgilentUSBHub ON                        ON
 +</​code>​
 +
 +
 +
 +== Power Distribution Units (PDU) ==
 +
 +At Katherine there are two power distribution units (PDU). These are like an 8 way power board that have individually switched outputs. They can be switched from a web interface at the following 2 links:
 +\\ [[http://​pdu1ke.phys.utas.edu.au/​outlet.htm|pdu1ke.phys.utas.edu.au/​outlet.htm]]
 +\\ [[http://​pdu2ke.phys.utas.edu.au/​outlet.htm|pdu2ke.phys.utas.edu.au/​outlet.htm]]
 +
 +The user is admin and the password is the same one we use for the internet power switches.
 +\\ PDU1KE so far has wifi, cduke (network maint computer) and the interior light.
 +\\ PDU2KE so far has mk5-2ke and the GPIB controller.
 +
 +