| * 18:30 UT - Experiment started ok. (Ellen) | * 18:30 UT - Experiment started ok. (Ellen) | ||
| * 00:34UT - Drive PC failed, had to halt the schedule and restart the Drive PC. Scans 282-0031 and 282-0037b are there, but may not be ok. (Imogen) | * 00:34UT - Drive PC failed, had to halt the schedule and restart the Drive PC. Scans 282-0031 and 282-0037b are there, but may not be ok. (Imogen) | ||
| + | * 06:34 UT - SX receiver parameter pressure is 4.9. Warren is going to drive out and fix it. (Ellen) | ||
| + | * 07:20 UT - The pressure is down to 1.8 and the temps are falling slowly back down. (Ellen) | ||
| **Katherine** | **Katherine** | ||
| Line 16: | Line 18: | ||
| * 02:20UT - Problem with mk5ke, have to switch to mk5-2ke to record to that until the other mark 5 is fixed. (Imogen) | * 02:20UT - Problem with mk5ke, have to switch to mk5-2ke to record to that until the other mark 5 is fixed. (Imogen) | ||
| * 03:56UT - changed mk5 over to mk5-2ke, began recording again. Autocorrelations on channels 1 and 14 are really not good, but all other channels are fine for now. (Imogen) | * 03:56UT - changed mk5 over to mk5-2ke, began recording again. Autocorrelations on channels 1 and 14 are really not good, but all other channels are fine for now. (Imogen) | ||
| + | * 06:00 UT - Autocorrelation has large spikes in bands 01 and 14. (Ellen) | ||
| + | * 06:30 UT - Since mk5-2ke is being used the "clkoff" values are wrong and will set off alarms every scan. I changed this in the log monitor to now only beep every scan (Configure > Delay Monitoring > Audible Warning). **The delay differences must be checked manually** using the command "clkoff-2" and comparing that with "maserdelay". (Ellen) | ||
| + | * 06:30 UT - Autocorrelation still bad in those 2 bands. (Ellen) | ||
| + | * 1200 UT -- Edited ''midob'' procedure to call clkoff-2 rather than clkoff. (Dave) | ||
| **Yarragadee** | **Yarragadee** | ||
| Line 23: | Line 29: | ||
| * 18:30 UT - Experiment started ok. (Ellen) | * 18:30 UT - Experiment started ok. (Ellen) | ||
| * 21:50 UT - The disc pos is already falling behind, while Ke and Ho are fine. I have noticed that Yg starts recording up to 5 seconds later than it should on some scans. (Ellen) | * 21:50 UT - The disc pos is already falling behind, while Ke and Ho are fine. I have noticed that Yg starts recording up to 5 seconds later than it should on some scans. (Ellen) | ||
| + | * 09:30 UT - Disc pos ~30 GB behind schedule. (Ellen) | ||