Please use this page to write up any notes on anything that needs to be passed on to the next observer or should go into the end of experiment message.
Notes should be placed below the horizontal line as a new blog entry.
Continuing problems should be copied to the Current Issues page.
Be sure to add any specific notes about the experiment if required, for example “Special back end configuration for x reason”. Put as much detail as you can - the more the better.
====== Experiment Name ====== **Hobart 12m** Disk VSN: abc-123 | Data volume at beginning: 2.34 GB * 1300UT a comment from me (user) **Katherine 12m** Disk VSN: | Data volume at beginning: GB * **Yarragadee 12m** Disk VSN: | Data volume at beginning: GB * 1300UT Experiment started okay (JMc).
Format for entering a comment It is important to stick to this formula - there is a good reason we need this information, so please include it!
Time stamp in UT * Comment * (Your Name)
For Example:
20:00UT: Wind stows, Missed scans 012-3456 to 012-3457 (Jim)
20:50UT: Mark5 lost connection, had to restart Mark5 and reconfigure DBBC, called Jamie on call to fix, missed scans 012-3456 to 012-4567 (Jim)
Again - as much detail as you can. It is important to remember that these notes will be sent to the correlator, so please make sure they make sense to others.
Hb:
Ke:
Yg:
Hb:
Ke:
Yg:
Ho:
Logs and EndMess sent (Lucia) All experiments started OK.
hb:
recording to HOB+0119 start at 8692 GB.
ke:
At UT13:40 day 241, the delay difference at Katherine started to drift quite badly, had to run fmset at 13.53UT (Imogen)
For some reason, gnuplot will not plot values of ke_ddif.txt past ~11:00UT - not sure why (Imogen).
At 14:29UT, restarted DBBC as clock drift was still occurring, ran fmset to resync dbbc and mark5. Delay seems to be stable as of 14:42UT, however cannot plot the values as they do not seem to be reaching the ke_ddif.txt file.
yg:
DISKS:
hb HOB+0119
ke HOB+0122
yg HOB+0120
1000 UTC: Int. T. reading red at 55 C. The internal temperature of the maser unit has risen to warning levels. Monica shows that the maser room temperature has risen since about 0 UTC on 27/8 reaching a peak at 0800 UTC and is now falling again. Brett informed. Martin to investigate in the morning (~2000 UTC).
1200 UTC: Int. T. now at 48 C and warning light off in maser monitor.
1300 UTC: Delay difference has been drifted since start of experiment. This seems to be coming from the formatter.
1315 UTC: Drift rate increased. Rebooting and formatting the DBBC.
2208 UTC: fmout seems to have been stable since UT18:00
1330 UTC: Resumed after reboot. Monitoring offsets.
1750 UTC: Delay difference drifting again. Trying another reconf.
2209 UTC: fmout seems to have been stable since UT18:00
0115 UTC: Large difference between formatter and GPS. Halted schedule to run fmset. This did not fix the problem. Jamie restarted the DBBC and reconfigured Schedule starting again at UT02:14.
0702 UTC: Formatter to GPS has remained stabled till the end of observations.