Came up on COM3, 9600 baud, 8 bit, parity none, stop bits 1, flow control none.
Connected power to logger via DC power-pack. No luck. Direct connection to battery works
MAC address for Array 1 00d02c04b057, Array 2 00d02c04b051 and temporary IP addresses are 131.217.62.92 and .93 respectively and called AUScope-Array1.phys… and AUScope-Array2.phys…
In Device Config Utility,
Connection over serial with ethernet plugged in, shown DHCP working and TCP port set to 6785
In Datalogger tab, Station name is Array1, PakBus Address 1, security code 0
edited .cipasswd file (New Services Tab) to give usual observer password for admin, FTP password for anonymous is the same
In logger Control, hit Set clock (synchs with PC clock, so that needs to be on an NTP server)
In data monitor, can see logged data (after plugging in sensors), other stats like batther level etc.
Finished, so disconnect.
Now in EZSetup Wizzard
IP address set to 131.217.62.92:6785, pakbus 1, security code 0
Comm test worked!
Configured Array2 as above, just different name and I address, PakBus Address 1 (tried 2 but failed the comms test).
/home/www/auscope/opswiki/data/pages/deformation/testsetup1.txt · Last modified: 2012/11/29 05:19 by Jim Lovell