This is an old revision of the document!
Hobart 26m
VSN module: HOB+1011/16000/1024 Beginning at : 1969.610 GB
Experiments started at: 17:41:08 UT, started late due to module VSN issue Missed scans: 1022-665 & 0537-441 Error being ignored: error qk -211 tsys value for device au overflowed or was less than zero Error being ignored: error qk -211 tsys value for device du overflowed or was less than zero Error being ignored: error ch -350 the receiver 20K stage is hotter than 40K Error being ignored: error ch -349 the receiver 70K stage is hotter than 85K
Katherine 12m
VSN module: HOB+0100/16000 Beginning at: 0.0 GB Experiment started OK Several warnings: warning error 5t -301 don't change mode while recording,use disk_record=off first or (dangerous) use disk_recors_ok as the sixth parameter Several warnings : error an -103 pointing computer tracking errors are too large
Yarragadee 12m
VSN module: HOB+0067 Beginning at: 0.0 GB Experiment started OK 17:41:26 UT : Auto stow released Several warnings: warning error 5t -301 don't change mode while recording,use disk_record=off first or (dangerous) use disk_recors_ok as the sixth parameter Several warnings : error an -103 pointing computer tracking errors are too large