Hb
Ke
Yg
Correlator notes:
+SUMMARY
Qcode % of Total % of Correlated
scans scans
5-9 83% 93%
0 2% 3%
4-1,A-H,N 4% 4%
Removed 11% -
+CORRELATOR_NOTES
+STATION_NOTES
HOBART12 (Hb/d): A few (5-10%) non-detections in S-band.
KATH12M (Ke/a): No data after UT 308-0511. Station reported:
YARRA12M (Yg/i): A few (5%) non-detections in S-band.
Problems: HOBART12 has a small clock break at ~06:27 (-.67 nsec).
YARRA12M has 3 small clock breaks, at ~17:11, ~23:30, and
~00:17. Only the 00:17 break (+.73 nsec) is set and the
others require deselecting a few dozen observations.
KATH12M died after the first 12 hrs, reason unknown.
Station Performance
Number of Observations
Scheduled Recoverable* Used % of scheduled
obs used
HOBART12 936 731 703 75.1% KATH12M 1108 581 552 49.8% YARRA12M 1078 862 796 73.8% --------------- --------- ----------- --------- ------ Station Total** 4418 3537 3341 75.6%
MISSED: Station was scheduled, but it did not observe.
NOT CORR: Station was scheduled but not correlated.
NOT USED: Usable data was generated for this station,
but the analyst rejected it all.