Remote connection to dBBC3 can be done via (addr: dbbc3[hb].*):
VNC connection with standard pwd
remote desktop with Windows XP user/pwd
Start DBBC3 Control
Select dBBC3 ops mode and version control. Initial options:
Select N Configure and N Initialise for a quick start and load of the pre-settings (1 min).
Select N Configure and Y Initialise for loading (5-10 min).
Select Y Configure to flash the firmware into the FPGA's and initialisation of the system (20 min).
Launch DBBC Client v4. exe to communicate and launch the dBBC3 commands.
Calibration of the DBBC3
Calibrate offset
Calibrate delay
Calibrate gain
Calibrate offset
dbbcif{a,b,c,d,e,f}=2,60 Set a strong attenuation for each of the IF.
* cal_offset={1,2,3,4,5,6} Launch the cal_offset program for each the Core boards.
/home/www/auscope/opswiki/data/attic/hardware/dbbc3.1550544598.txt.gz · Last modified: 2019/02/19 02:49 by Guifre