Chair: Ross

Present:

Apologies:

Absent:

General Issues:

Handover Issues:

  • RD1704 VC rack timing out - had to travel out to Mt. P to reset the VC rack and the TTY Distributor.
    • Due to power failure
    • Strongly recommended to do setup on the previous day.
  • equip.ctl file check?
  • Wind sensor at hb locked up - continuous wind stow. Do we have a fix for this in the wiki?
    • Ke & Yg (?) have IP switches - Requires turning off and on again.
    • Anemometer locked up - restart monica.weather (standard monica restart process)
  • Network issues at Ke - R1784
    • Lost communication to VPN and Ke network. CMOS battery died in pcfske, rebooted, but wouldn't reconnect to network. Had to reboot pcfske through mk5ke. Might need to follow up on network configuration for the pcfske machine.
    • If you can't ping a machine from outside a site, try pinging from something else on the local network.
  • Sending off logs - Ross had problems sending off the logs for R1785. Flogit backup script flogit_auscope.bkg.pl can be used if you have issues with the ftp to France.