Please use the Transfers Page for information on data transfer.
See the Modules Page
Please enter any significant events related to the AuScope VLBI project, including observations, configuration changes, hardware upgrades etc.
Installed the following packages on mk5hb and/or mk5ke
Thanks to Ed Himwich and Jonathan Quick, a reliable procedure for configuring the counters has been found. The key was to replace the :meas:tint? with :func 'tint 1,2'. The new counter procedure is as follows:
define counter 10278223006x "setting up agilent counters hpib=ca,*rst hpib=ca,:func 'tint 1,2' hpib=ca,:even1:hyst:rel 10 hpib=ca,:even1:lev:abs 0.9v hpib=ca,:even1:slop pos hpib=ca,:inp1:att 1 hpib=ca,:inp1:coup dc hpib=ca,:inp1:filt off hpib=ca,:inp1:imp 50 hpib=ca,:even2:hyst:rel 10 hpib=ca,:even2:lev:abs 0.9v hpib=ca,:even2:slop pos hpib=ca,:inp2:att 1 hpib=ca,:inp2:coup dc hpib=ca,:inp2:filt off hpib=ca,:inp2:imp 50 hpib=ca,:init:auto off hpib=ca,:init:cont on " hpib=cb,*rst hpib=cb,:func 'tint 1,2' hpib=cb,:even1:hyst:rel 10 hpib=cb,:even1:lev:abs 0.9v hpib=cb,:even1:slop pos hpib=cb,:inp1:att 1 hpib=cb,:inp1:coup dc hpib=cb,:inp1:filt off hpib=cb,:inp1:imp 50 hpib=cb,:even2:hyst:rel 10 hpib=cb,:even2:lev:abs 0.9v hpib=cb,:even2:slop pos hpib=cb,:inp2:att 1 hpib=cb,:inp2:coup dc hpib=cb,:inp2:filt off hpib=cb,:inp2:imp 50 hpib=cb,:init:auto off hpib=cb,:init:cont on enddef
Gmail and Skype accounts have been set up for operations at each telescope site. More information on the Operator Documentation page.
1958 UTC 21 Sep 2010 The software update is finished. Mark Godwin
1945 UT 21 Sept 2010 Starting an update to the Hobart 12m Antenna Controller. Should take no more than one hour. Will notify when complete. Mark Godwin