**Hobart 12m**

Disk VSN: abc-123 | Data volume at beginning: 2.34 GB

   * 1300UT a comment from me (user)

**Katherine 12m**

Disk VSN: | Data volume at beginning:  GB

   * 

**Yarragadee 12m**

Disk VSN: | Data volume at beginning:  GB

   * 1300UT Experiment started okay (JMc).

Format for entering a comment It is important to stick to this formula - there is a good reason we need this information, so please include it!

Time stamp in UT * Comment * (Your Name)

For Example:

20:00UT: Wind stows, Missed scans 012-3456 to 012-3457 (Jim)

20:50UT: Mark5 lost connection, had to restart Mark5 and reconfigure DBBC, called Jamie on call to fix, missed scans 012-3456 to 012-4567 (Jim)

Again - as much detail as you can. It is important to remember that these notes will be sent to the correlator, so please make sure they make sense to others.


R1703

Ho

VSN: USN-0111

  • UT 1701 experiment started OK. Can't find r1703ho.sum, prc files etc seem to have drudged okay, but oper@hobart /tmp/sched.tmp looks to be for previous experiment still. (JS)
  • UT1730 The default attenuations are sufficient to keep the voltages in the appropriate range - leaving them (JS)
  • UT0650 vacuum pump switched on because receiver was slowly warming up. (Lucia)

Ke

VSN: HOB+0047 0GB

  • UT 1704 experiment started okay (JS)

Yg

VSN: USN-0035 0GB

  • UT 1704 experiment started okay (JS)
2015/08/31 14:45 · 0 Comments
R4702

Ho

VSN: USN-0002

Ke

VSN: USN-0002

  • “2015.240.07:56:48 ALARM: Delay through DBBC has changed. Monitor for stability and reset DBBC if it drifts.” Looked at delay differences, but they didn't seem to have jumped (before alarm -0.280us and after -0.285, -0.282 etc). Since couldn't see anything else wrong, Jim said we could ignore it for the moment. (Anita)
  • 08:26:51 got that alarm again. This time seems like there is a small drift in the delay difference - keeping an eye on it (Anita)
  • 14:19 UT - Same alarm again. No problems as far as I could tell. (Ellen)

Yg

VSN: SHAO-010

  • 1905 UT: Windstow activated. Appears to be a misread on windy or the anemom (wind speed 9999 km/h). Reset the windyg box to bring the average windspeed back down. Misreads continued. Did cold reset on windyg. Still the occasional misread. Could be on the anemometer end (An insect on the ultrasound transducers?).
  • Scans missed: 239-1906b – 239-1918, 239-1929, 239-1934b
2015/08/27 19:28 · 0 Comments
RD1507

Hobart 26m:

Disk VSN: HOB+1004

Data volume at beginning: 1025 GB

AOV004

Katherine 12m:

Disk VSN: HOB+0110

Data volume at beginning:RD 0 GB

  • 00:45 UT: alarm through DBBC has changed in last digit. Might cause one of these small cklock jumps. (Lucia)
  • 02:07 UT: dbbc kept drifting. Schedule halted, dbbc reset, fs restarted. First good scan 239-0210. Missed 90 GB. (Lucia)
  • 09:57 UT: ALARM: Delay through DBBC has changed. Monitor for stability and reset DBBC if it drifts. Delay is not stable, dbbc keeps drifting, schedule halted and dbbc reset. Missed scans 239-0957 and 239-1007 (Ross).

Yarragadee 12m:

Disk VSN: HOB+0083

Data volume at beginning: 0 GB

  • SETUP: ntpq has highly unstable offset in fifth row ranging between -13 and -22 ms. First two are stable, and third and fourth are consistently less than 10 ms (Ross).
  • SETUP: Cannot record to HART+101 module in Bank A. Module HOB+0083 in bank B can successfully be recorded to (Ross).
2015/08/26 14:35 · 0 Comments
R1702

Ho:

VSN: BKG-0006

Offset: 0

  • Exp started late as need to change receiver from last exp. (Dave)
  • Dubious attenuation and tsys til 1720. (Dave)

Ke:

VSN: HART-015

Offset: 0

  • Good pointing fit (Dave)
  • Fringes found with Yg (Dave)

Yg:

VSN: IAA-0028

Offset: 56.6 GB

  • 236/0730 UT: Could not record to module IAA-0028 in Bank A of mk5yg — Dimino locks up and requires killing. Could record to HART+101 in Bank B OK. Swap modules: IAA-0028 to Bank B, HART+101 to Bank A. Can't record to HART+101 in Bank A without dim locking up either. Bank A is misbehaving. If we need to swap modules, it may need to go into Bank B. Resetting mk5yg did not fix the problem. (Dave)
  • Good pointing fit (Dave)
  • Fringes found with Ke (Dave)
2015/08/24 07:38 · 0 Comments
R4701

Hobart 26m:

Disk VSN: USN-0182

Data volume at beginning: 0 GB

02:16 UT - Windstows. Halted schedule at 02:19UT for safety reasons (Imogen)

Consistent windstows all day. No good data from 02:16UT until 05:35UT (Imogen)

  • Windstowed from 07:15 UT till 9:37. Scans affected: 233-0717b to 233-0936 inclusive. (Ellen)
  • 08:05 UT - Cryo vacuum pressure 2.9 and 70K stage at 62 - keeping an eye on them. Disc pos ~30 GB AHEAD. (Ellen)
  • 09:23 UT - “ALARM: error m5 -104 mk5cn: time-out, connection closed”. I checked and the mk5a was running and there were no problems next scan. So I'm not sure what this was about. (Ellen)

Katherine 12m:

Disk VSN: HAY-0017

Data volume at beginning: 0 GB

  • 10:48 UT - “ WARNING: error st -27 computer acu time difference exceeded 0.25 seconds”. Scan 233-1048b affected. Delay difference was fine. Had to run fmset between scans. Halted schedule and missed half of scan 233-1051c. (Ellen)

Yarragadee 12m:

Disk VSN: USN-0039

Data volume at beginning: 0 GB

2015/08/20 14:37 · 0 Comments
VEPS06

Hobart 26m:

Recording through MkIV rack and DBBC simultaneously.

For MkIV rack, pcfs running on VNC session newsmerd:1 as usual. DBBC running through field system on pcfsho:1.

eRemoteCtrl and log monitor for MarkIV only

Disk VSN: MarkIV recording to HOB+0074 (Mark5A), DBBC recording to HOB+0072 (Mark5B+)

Data volume at beginning: 0

-Jim

  • 14:45 UT - MarkIV disk pos 46 GB behind, while DBBC is 30 GB behind. (Ellen)
  • 16:55 UT - MarkIV disk pos 45 GB behind, while DBBC is 36 GB behind. (Ellen)
  • 19:04 UT - MarkIV disk pos 53 GB behind, while DBBC is 43 GB behind. (Ellen)
  • 21:55 UT - MarkIV disk pos 64 GB behind, while DBBC is 51 GB behind. (Ellen)