This is an old revision of the document!
Hobart 26m
Disk VSN: HOB +0119/32000 | Data volume at beginning: 2050.764 GB
Received error “Problem connecting to metserver socket” for every scan (mas)
18:00 UT Experiment started OK (mas)
18:37:40 UT Log monitor started to report negative disk usage for some of the scans (mas)
19:53 UT Halt schedule to sync the Field System clock. Missed scans no0022 & no0023 (mas)
07:00 UT - Noticed autocorrelation spectra was not updating. Checked procedure file (compared to aua043) and noticed it was missing a bunch of procedures (including postob, which produces the spectra). Copied those procedures into the aua045ho.prc file, and reloaded it with `proc=aua045ho`. Now the spectra are showing up, and they look fine (Patrick)
Katherine 12m
Disk VSN: HOB +0117/32000 | Data volume at beginning: 9949.077 GB
18:00 UT Experiment started OK (mas)
Received “Warning: error tc -301 continuous cal not enabled for DBBC” for every scan (mas)
18:18:45 UT Log monitor started to report negative disk usage for some of the scans (mas)
Yarragadee 12m
Disk VSN: MAT +0003/8000 | Data volume at beginning: 0.00 GB
18:00 UT Experiment started OK (mas)
18:12:08 UT Log monitor started to report negative disk usage for some of the scans (mas)
18:15:30 UT Halt schedule and tried to sync the seconds decimal for Field System and computer (0.02 micro seconds difference with Mark5) but couldn't sync. Maserdelay and clkoff are OK. Missed scans no00005 & no00006 (mas)