Hb
Ke
Yg
error for fringe check: not successful. Automatically selected source was not visible from Yg (antenna limits reached).
Qcode % of Total % of Correlated
scans scans
5-9 92% 93% 0 4% 4% B-H 2% 2% Removed 1%
Qcodes 7-9 Correlated 92% Qcode N Not Correlated 0%
+CORRELATOR_NOTES
+STATION_NOTES
HOBART12 (Hb/H): Station experienced large clock drifts from start
of session to 303-2028.
Clock again drifted after approximately 303-0130,
continuing until DBBC reset at 304-0407.
Low fringe amplitudes in channel SR6U,
leading to occasional 'G' codes.
Channel SR6U removed from fringe fitting.
KATH12M (Ke/A): Ok. YARRA12M (Yg/Y): Ok.
+DROP_CHANNELS
Ft SR4U Hb SR6U
Other comments: a clock break in clock rates reported by the correlator for HOBART12. The effect is visible only for the single band delays, no additional break were added to the station. A small clock break is on YARRA12M baselines at the X-band.
Session Statistics
Observations: 2104 scheduled
2031 correlated (in database)
1853 recoverable (usable)
1783 used
Session fit: 36.421 ps
Station Performance
Number of Observations
Scheduled Recoverable* Used % of scheduled
obs used
HOBART12 471 387 369 78.3%
KATH12M 546 495 480 87.9%
YARRA12M 504 447 431 85.5%
--------------- --------- ----------- --------- ------
Station Total** 2104 1853 1783 84.7%
MISSED: Station was scheduled, but it did not observe.
NOT CORR: Station was scheduled but not correlated.
NOT USED: Usable data was generated for this station,
but the analyst rejected it all.