This wiki is not maintained! Do not use this when setting up AuScope experiments!
Chair: Katie
next week's chair: Simin
Attended: Gabor, Lim, Prad, Jay
Apologies: Tiege, Jamie, Patrick
Absent: Lucas, Simin, Mas
General Issues
DBBC software needed a couple of restarts due to the well known TPI overflow issue when doing a pointing check.
Handover Issues
R1913
Yg: 1700UT error m5 -900 not whilst recording and error m5 -906 mark5 return code 6: inconsistent or conflicting request seems to happen on every scan.The above error is due to mk5=bank_set? being called during midob. Commented out mk5=bank_set? in midob and moved it to preob. Temporary fix documented here (Lucas)
T2134
Ho: Something with the wx command. Keep getting 'Problem connecting to metserver socket' and 'illegal error class code' (Prad).
Warren said he would fix.
R1914
Yg:13:20UT - Network connection between ops8 and pcfsyg down. Can't connect to yg-via-internode. Monitoring, in case it comes back up. Network restored. Contacted Yg and checked everything was operational on their end. Asked them to reboot/power cycle router, but they weren't sure which one (neither was I). Just about to call on-call person, then it came back up.
/home/www/auscope/opswiki/data/pages/operations/agenda2019_10_03.txt · Last modified: 2019/10/03 03:07 by Katie Vandorou