Check the Status Monitor to see if the Cross-over switches and RCP IF Attenuators are at the default levels:
@@TT
__QQ
TTNN
Check the crossover switch and attenuator settings via the System Monitor GUI.
The main thing is that the target power levels (listed in the next session DBBC setup) are OK. If values aren't as above, but power levels are attained without radical attenuation, then all is well. Otherwise, the attenuation level should be adjusted using the rfpic
and ifpic
commands in the Field System. Documentation for these commands is here:
but each station has setup procedures for the default settings. Cross-over switched to Direct:
xodirect
IF attenuation to nominal:
ifnom
To set these values manually, use the nc (netcat) command and appropriate ASCII code given above. For example, to set the attenuators at Yarragadee, log in as oper to pcfsyg and type:
nc pcfsyg 60002 S
Prompt will return: 'values', so type in:
TTNN
Then type “Ctrl-C” to quit