This is an old revision of the document!
Now make a test recording using the Mark5. This is done through the Operator Input window.
disk_record=on mk5=dot? (Output should appear as before, but it should say FHG_on) disk_record=off
Now check the data are OK:
scan_check
Check the last numbers are the correct date at the start of the scan, duration, the data rate (should be 256 for the 8MHz mode, 128 for the 4 MHz mode) and 0 at the end for no problems. Then plot an autocorrelation from the data:
postob
The output should appear in the pcfs[hb|ke|yg] VNC session. Good data should contain quite flat bandpasses and zero phase. See autocorrelation spectra plots for an example and what problems to look out for. If there's a problem, the DBBC may need reconfiguring.
To clear the disk module, ONLY IF YOU'RE CERTAIN there is no data already on the disk!
mk5=protect=off; mk5=reset=erase
Check that the spectra are OK. If there are dropped or strange-looking bands, the DBBC may need reprogramming.